{"title":"Display \u0026 electronics","description":"","products":[{"product_id":"anschlussklemme-fur-verbindung-puffersensors","title":"Board connector Attack for the connection of the buffer sensor to the control board","description":"\u003ch2\u003eConnection terminal Attack board connector \u003c\/h2\u003e  \u003cp\u003e\u003cstrong\u003eThe circuit board connector for connecting the buffer sensor to the control board\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003e Connection terminal Attack is for boilers Attack SLX Lambda Touch and Attack Wood \u0026amp; pellet suitable.\u003c\/li\u003e  \u003cli\u003eAttack terminal block for connecting the buffer sensor to the control board of Attack SLX Lambda Touch and Attack Wood boilers \u0026amp; Pellet. \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":47010470953308,"sku":"APS","price":4.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/platinenstecker-attack-fur-die-verbindung-des-puffersensors-mit-der-steuerplatine-1042463.webp?v=1770693204"},{"product_id":"steuerplatine-attack-slx","title":"SIGMATEK control board for Attack Wood \u0026 Pellet and SLX Lambda Touch","description":"\u003ch2\u003eSIGMATEK control board for Attack Wood \u0026amp; Pellet and SLX Lambda Touch\u003c\/h2\u003e  \u003cp\u003eThe SIGMATEK control board is the ideal solution for the optimal control of pellet combination boilers and wood gasification boilers. Thanks to state-of-the-art technology, it ensures precise combustion monitoring and improved efficiency. It is particularly suitable for the Attack Wood models. \u0026amp; Pellet and SLX Lambda Touch.\u003c\/p\u003e  \u003ch3\u003eProduct information\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eMain control board\u003c\/li\u003e  \u003cli\u003eSuitable for Attack SLX Lambda 20 - 55 kW\u003c\/li\u003e  \u003cli\u003esuitable for Attack Wood \u0026amp; Pellet\u003c\/li\u003e  \u003c\/ul\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":47010471510364,"sku":"ASLXLSP","price":865.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/steuerplatine-sigmatek-fur-attack-wood-pellet-und-slx-lambda-touch-5632530.webp?v=1770693271"},{"product_id":"attack-anlaufkondensator-2mf","title":"Attack starting capacitor 2mF for FCJ4C82SE 400V metal capacitor","description":"\u003ch2\u003eAttack starting capacitor 2mF\u003c\/h2\u003e  \u003cp\u003eAttack starting capacitor 2mF to FCJ4C82SE 2 microF\/400V\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49318538805596,"sku":"AAK2M","price":12.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/attack-anlaufkondensator-2mf-fur-fcj4c82se-400v-metallkondensator-5176889.png?v=1770692782"},{"product_id":"attack-anlaufkondensator-1mf","title":"Attack starting capacitor 1mF replacement part for FCJ4C52S","description":"\u003ch2\u003eAttack starting capacitor 1mF\u003c\/h2\u003e  \u003cp\u003e\u003cstrong\u003e Attack replacement part for FCJ4C52S 1 microF\u003c\/strong\u003e\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49318996312412,"sku":"AAK1M","price":12.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/attack-anlaufkondensator-1mf-ersatzteil-fur-fcj4c52s-4763556.png?v=1770692782"},{"product_id":"attack-endschalter-fur-obere-tur","title":"Attack limit switch for upper door","description":"\u003ch2\u003eAttack limit switch for upper door \u003c\/h2\u003e  \u003cp\u003eAttack Door switch\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49352253276508,"sku":"ATES","price":36.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/attack-endschalter-fur-obere-tur-2868360.png?v=1770692731"},{"product_id":"attack-steuerelektronik-rk-200","title":"Attack control electronics RK-200 for professional applications","description":"\u003ch2\u003eAttack Control Electronics RK-200\u003c\/h2\u003e\u003cp\u003eThe Attack control electronics are a state-of-the-art control unit specifically designed for the precise control and monitoring of heating systems. The RK-200 control electronics impress with its reliability, user-friendly interface, and numerous integrated protection functions that ensure the efficiency and safety of the heating system.\u003c\/p\u003e\u003cp\u003eType: PROFI PID RK-2001ATW – This version of the control electronics uses advanced PID control technology to precisely control temperature and other operating parameters. The Attack RK-200 control electronics allow for optimal adaptation to varying heating requirements, thus contributing to economical and environmentally friendly energy use. Thanks to versatile connection options and flexible programming capabilities, the control electronics are suitable for use in both private households and industrial applications.\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49515212276060,"sku":"ASE","price":279.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/attack-steuerelektronik-rk-200-fur-professionelle-anwendungen-2931739.webp?v=1770692551"},{"product_id":"attack-touch-display-7","title":"Attack SLX Touch Display 7 inches","description":"\u003ch2\u003eAttack Touch Display 7\"\u003c\/h2\u003e  \u003cp\u003eThe Attack Touch Display 7\" This is a high-quality, genuine replacement part specifically designed for Attack heating systems. This modern touchscreen display offers an intuitive user interface, allowing you to conveniently control all the functions and settings of your unit. The clear, 7-inch display ensures excellent readability and ease of use in both residential and professional settings. By using this genuine replacement part, you ensure the continued compatibility and optimal performance of your Attack system. Rely on the Attack Touch Display to guarantee the long-term reliability and functionality of your system.\u003c\/p\u003e  \u003ch3\u003eProduct information\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eSuitable for Attack SLX Lambda 20 - 55 kW\u003c\/li\u003e  \u003cli\u003esuitable for Attack Wood \u0026amp; pellet\u003c\/li\u003e  \u003c\/ul\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49515358880092,"sku":"ATD","price":1058.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/attack-slx-touch-display-7-zoll-8644547.webp?v=1770692562"},{"product_id":"steuer-leistungselektronik-control-electronics-fur-pelletbrenner-attack-ek025-ersatzteil-h30806b","title":"H30951B Control and power electronics for ATTACK DPX Combi Pellet 25\/30\/35, PELH30A \u0026 PELHB25","description":"\u003ch2 class=\"mt-6 mb-2 font-semibold text-3xl\" data-streamdown=\"heading-1\"\u003eH30951B Control\/power electronics for Attack pellet burner\u003c\/h2\u003e  \u003cp\u003eThe \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30951B Control\/Power Electronics\u003c\/span\u003e is the central control and power module for various \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eAttack Pellet Burner\u003c\/span\u003e and \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eCombined boiler systems\u003c\/span\u003eIt takes over the complete control, monitoring and power management of all relevant components in pellet operation.\u003c\/p\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eCompatible attack devices (excerpt)\u003c\/h3\u003e  \u003cp\u003eAccording to exploded views and spare parts lists, the H30951B is installed in, among others, the following Attack devices:\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK DPX COMBI PELLET 25, 30, 35\u003c\/span\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ez.B. Device family \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003e#110 PELH30ACP\u003c\/span\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eConstruction periods u.a.: 10\/2014 – 7\/2018 and from 8\/2018 (depending on the version)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELH30A\u003c\/span\u003e (Pellet burner unit, from 10\/2014)\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELHB25\u003c\/span\u003e (Pellet burner 25 kW, from 10\/2014)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003eThe H30951B is listed there as a separate item in the spare parts plan and is part of the assemblies with the codes z.B.:\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePELH30A\u003c\/span\u003e, \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePELHB25\u003c\/span\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eIn combination with other relevant components such as H30970A, H30806B, H30808, H30809, H30820, H30980, ADF25640, PELH30830A u.v.m.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003eThis makes the H30951B particularly suitable for \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eAttack pellet burners in the power range of 25 to 35 kW\u003c\/span\u003e relevant, which are found in various boiler series such as \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eDPX Combi Pellet\u003c\/span\u003e be used.\u003c\/p\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eFunction and tasks of the H30951B\u003c\/h3\u003e  \u003cp\u003eThe H30951B is a combined \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eControl and power electronics\u003c\/span\u003eIt handles both the intelligent control (microcontroller control) and the control of the consumers (power section):\u003c\/p\u003e  \u003col class=\"list-inside list-decimal whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"ordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eBurner control (Control Electronics)\u003c\/span\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eEvaluation of sensors (z.BTemperature sensor, exhaust gas temperature, flame sensor, possibly vacuum sensor)\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eControl of the process flow of: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eStarting and ignition process\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eTransition to continuous operation\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ePower modulation\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003econtrolled shutdown process\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eImplementation of the heating programs and safety strategies stored in the device\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePower control (Power Electronics)\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eControl of: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePellet auger(s)\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eIgnition device\/ignition cartridge\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eBlower\/combustion fan\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ecleaning and discharge mechanisms (if applicable)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eSwitching of consumers via relays or...electronic circuit breakers\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ePower supply for the control electronics and the connected sensors\/actuators\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eSecurity and incident management\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eMonitoring of overtemperature, flame loss, underpressure or exhaust gas faults\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eIntroduction of \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003esafe shutdown\u003c\/span\u003e in case of malfunction\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eEdition of \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eError codes\/fault messages\u003c\/span\u003e to the control unit of the Attack boiler\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eCommunication with control unit and boiler control\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eInterface to the operating and display unit (display, buttons)\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eTransfer of status, temperature and fault information\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eInteraction with the higher-level boiler or heating control system (release, power request)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003c\/ol\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eTypical errors that indicate a control system malfunction\u003c\/h3\u003e  \u003cp\u003eThe \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30951B Control\/Power Electronics\u003c\/span\u003e is considered \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ecomplete replacement module\u003c\/span\u003e used when:\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ethe \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePellet burner no longer starts\u003c\/span\u003e or goes out uncontrollably\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eIndividual outputs (ignition, auger, fan) can no longer be controlled, even though the components themselves are fine.\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eRecurring or unexplained error messages\u003c\/span\u003e problems occur that cannot be attributed to sensors, wiring, or peripherals\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eVisible damage to the electronics is present (burnt components, defective relays, swollen capacitors)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003eBy replacing the H30951B, the \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003efull range of functions of the pellet burner\u003c\/span\u003e It can be restored, provided all other components are intact.\u003c\/p\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eAdvantages of the original H30951B for Attack pellet burners\u003c\/h3\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eOriginal spare part\u003c\/span\u003e matching the corresponding Attack series\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003etailored to: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK DPX COMBI PELLET 25, 30, 35\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELH30A\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELHB25\u003c\/span\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eensures \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ecorrect combustion\u003c\/span\u003e, high efficiency and stable performance in pellet operation\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003esecures the \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eCompliance with safety functions\u003c\/span\u003e according to manufacturer's specifications\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eoptimal compatibility with other Attack components (z.B. PELH30851, PELH30800A, PELH30807B, PELH30830A, sensors TS215, TH31, TH23A etc.)\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eImportant information regarding ordering and exchanges\u003c\/h3\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ePlease note before ordering: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eBoiler\/burner nameplate\u003c\/span\u003e check (z.BATTACK DPX COMBI PELLET 25\/30\/35, Year of manufacture\/Serial number)\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eexisting electronic circuit board to the marking \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30951B\u003c\/span\u003e control\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eFor safety reasons, replacement should be carried out by a \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eSpecialist company\/heating specialist\u003c\/span\u003e take place: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eMains voltage 230 V\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eCorrect connection assignment and parameterization required\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eIf necessary, adaptation to existing sensors and peripherals\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eScope of delivery\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003e1x original Attack control board \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30951B\u003c\/span\u003e  \u003c\/li\u003e  \u003c\/ul\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":56543461146972,"sku":"APSP","price":305.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/h30951b-steuer-leistungselektronik-fur-attack-dpx-combi-pellet-253035-pelh30a-pelhb25-7132351.webp?v=1770692015"},{"product_id":"steuer-elektronikplatine-die-speziell-fur-die-automatische-reinigung-des-rosts-grates-beim-pelletbrenner-attack-ek049","title":"Attack H30806B electronic module for automatic cleaning of the pellet burner grate - original ATTACK replacement part for DPX Combi Pellet \u0026 Pellet 30 Automatic Plus","description":"\u003cp\u003eAttack H30806B – Electronics for cleaning the pellet burner grate\u003c\/p\u003e  \u003cp\u003eThe spare part number \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30806B\u003c\/span\u003e from \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK\u003c\/span\u003e refers to an electronic module for \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eAutomatic cleaning of the pellet burner grate (Grate Cleaning Electronics)\u003c\/span\u003e.  It is used in various ATTACK pellet boilers and combination boilers and is a key element for reliable, clean and efficient operation.\u003c\/p\u003e  \u003ch2 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eProduct description\u003c\/h2\u003e  \u003cp\u003eThe \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eAttack H30806B Electronics for cleaning the pellet burner grate\u003c\/span\u003e is a specially developed control board that the \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eBurner grate cleaning mechanism\u003c\/span\u003e (Burner pot) in ATTACK pellet systems. It ensures that ash and slag are regularly removed from the grate and that the air supply for combustion remains unobstructed. An optimal \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eSystem compatibility is achieved.\u003c\/span\u003e,  since it is a \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eoriginal ATTACK spare part\u003c\/span\u003e deals and offers a \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003estable combustion\u003c\/span\u003e and a high efficiency.\u003c\/p\u003e  \u003cp\u003eDepending on the device, the module controls the corresponding \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eMotor or drive\u003c\/span\u003e It is used for rust cleaning and works in conjunction with the boiler's main control system. This allows the cleaning cycles to run automatically and safely – without operator intervention.\u003c\/p\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eFunction and benefits\u003c\/h3\u003e  \u003ch4 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eMain tasks of the H30806B electronics\u003c\/h4\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eControl of the rust cleaning\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eSwitches and controls the motor or drive for the mechanical cleaning of the combustion grate.\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eControls direction of rotation, running time and cycles according to the specifications of the boiler control system.\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eAutomatic cleaning cycles\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eActivates cleaning at defined intervals or operating conditions (e.g., after burner operation, when starting\/shutting down)\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ePrevents the rust openings from becoming clogged with ash and slag.\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eImproved combustion and efficiency\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eClean grate = unobstructed airways = stable flame and high efficiency\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eReduction of ignition problems, flameouts and malfunctions caused by slagging of the burner pot\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eProtection of burner and system\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eRelief for the mechanical components of the cleaning process\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eLonger lifespan of burner and boiler\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eIn conjunction with the main control unit, error messages can be issued in case of a malfunction (e.g., blocked grate).\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eCompatible ATTACK models (excerpt)\u003c\/h3\u003e  \u003cp\u003eThe electronics \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30806B\u003c\/span\u003e is used in several ATTACK pellet appliances, including:\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK DPX COMBI PELLET 25, 30, 35\u003c\/span\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ee.g. in the assembly \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePELH30ACP\u003c\/span\u003e (Combination boiler wood\/pellet)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK DPX COMBI PELLET 40, 45, 50\u003c\/span\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ein the pellet burner\/pellet module area of ​​the assembly \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePELH50ACP\u003c\/span\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELLET 30 AUTOMATIC Plus\u003c\/span\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ein the assembly \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePELH30 Plus\/PELH30PLUS\u003c\/span\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELH30A\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELHB25\u003c\/span\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003eNote: The specific application may vary slightly depending on the year of manufacture and version (according to the exploded view\/spare parts list). The documentation for your specific model is authoritative.\u003c\/p\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003ePossible errors that indicate a defective circuit board\u003c\/h3\u003e  \u003cp\u003eThe \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30806B‑Electronics\u003c\/span\u003e is the right replacement part if:\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ethe \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eThe rust cleaning mechanism is no longer working.\u003c\/span\u003e,  even though the boiler starts a cleaning cycle\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ethe motor of the rust removal system is not activated or only sporadically\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003emore \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eError messages related to burner cleaning\u003c\/span\u003e appear\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ethe burner pot becomes unusually clogged with ash\/slag quickly, even though the fuel and settings are unchanged.\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eInstallation note\u003c\/h3\u003e  \u003cp\u003eThe exchange of \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eAttack H30806B Electronics of cleaning the pellet burner grate\u003c\/span\u003e should be exclusively by a \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eauthorized specialist company\u003c\/span\u003e or by a qualified electrician. When working on electronics, the relevant safety regulations, manufacturer's instructions and device approvals must be observed.\u003c\/p\u003e  \u003ch3\u003eScope of delivery\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003e1 x original Attack control board H30806B\u003c\/li\u003e  \u003c\/ul\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":56543537758556,"sku":"APRP","price":165.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/attack-h30806b-elektronikmodul-fur-automatische-reinigung-des-pelletbrenner-rostes-original-attack-ersatzteil-fur-dpx-combi-pellet-pellet-30-automatic-plus-7936067.webp?v=1770692014"}],"url":"https:\/\/at.gemashop.de\/en\/collections\/display-electronics.oembed","provider":"GEMA Shop","version":"1.0","type":"link"}