{"product_id":"gema-hygienespeicher-fks-300-319-l-edelstahlwellrohr-waermetauscher","title":"GEMA hygienic storage tank FKS 300 – 319 l with stainless steel corrugated pipe and lower heat exchanger","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe GEMA hygienic storage tank FKS 300 is a standing fresh water combination storage tank with a net capacity of 319 l. It combines the function of a heating buffer tank with hygienic domestic hot water heating via an internal stainless steel corrugated pipe.\u003c\/p\u003e \u003cp\u003eThe storage tank is suitable for heating systems in which heating water is to be stored and domestic hot water is to be heated on demand using the flow-through principle. Thanks to the lower heat exchanger, the storage tank can be integrated into suitable system concepts with additional heat generators or system components.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe FKS 300 features a storage tank for heating water, a stainless steel corrugated pipe for domestic hot water heating, and a lower heat exchanger with a surface area of 1.2 m². The heating surface of the stainless steel corrugated pipe is 5 m². The storage tank is designed for a maximum operating pressure of 5 bar, and the maximum operating temperature is 95 °C.\u003c\/p\u003e \u003cp\u003eFor hydraulic integration, 8 charging and discharging connections with 1 1\/2\u0026quot; female thread, 4 sensor and controller connections with 1\/2\u0026quot; female thread, and one vent connection with 1 1\/4\u0026quot; female thread are available. Two connections for electric heating elements with 1 1\/2\u0026quot; female thread are provided.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eDomestic hot water heating via the stainless steel corrugated pipe supports hygienic hot water preparation without permanently storing domestic hot water in the storage tank. At the same time, the storage tank provides heating water for the system and can therefore be used as a central component in compact heating and hot water solutions.\u003c\/p\u003e \u003cp\u003eWith a base diameter of 600 mm without insulation and a height of 1,300 mm, the FKS 300 remains comparatively compact. The available EPS insulation variants allow insulation to be adapted to the desired configuration.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe lower heat exchanger allows the integration of additional heat generators or system components as part of appropriate system planning. The tank is intended for operation with heating water on the tank side and for domestic hot water heating via the stainless steel corrugated pipe.\u003c\/p\u003e \u003cp\u003eWhen using a heating cartridge, only the designated connections may be used. Safety valves, expansion vessels, venting, and fittings must be designed to suit the respective system.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eProduct type\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eSanitary storage tank \/ fresh water combination tank\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eStorage volume\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e319 l net content without heat exchanger\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSanitary function\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eDomestic hot water heating via stainless steel corrugated pipe\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeat exchanger\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1 lower heat exchanger\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeight without insulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1,300 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWidth without insulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e600 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDepth without insulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e600 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWeight without insulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e107 kg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure of storage tank\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e5 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e95 °C\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe storage tank is set up standing on a load-bearing, level surface and aligned vertically. Sufficient space must be planned for installation, maintenance, sensors, connections, and insulation. The tilting dimension without insulation is 1,300 mm.\u003c\/p\u003e \u003cp\u003eThe insulation should only be installed after the tank has been set up and the connection positions have been checked. Unused connections must be properly sealed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eInstallation, connection, and commissioning may only be carried out by qualified personnel. The storage tank may only be operated within the specified pressure and temperature limits and in frost-free indoor areas.\u003c\/p\u003e \u003cp\u003eThe drinking water connections must be executed in accordance with applicable hygiene and installation regulations. Operating pressure, operating temperature, tightness, and safety valves must be checked regularly.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eGEMA hygienic storage tank FKS 300\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Schönberg","offers":[{"title":"100mm","offer_id":57377793114460,"sku":"FKS300+EEKC","price":1479.05,"currency_code":"EUR","in_stock":true},{"title":"130mm","offer_id":57377793147228,"sku":"FKS300+EEKB","price":1669.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Hygienespeicher_mit_1_Waermetauscher.png?v=1782221015","url":"https:\/\/at.gemashop.de\/en\/products\/gema-hygienespeicher-fks-300-319-l-edelstahlwellrohr-waermetauscher","provider":"GEMA Shop","version":"1.0","type":"link"}