{"product_id":"ibc-gk-7k-oeko-36-holzvergaser-36kw","title":"IBC GK-7K öko 36 wood gasification boiler – 36 kW","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe IBC GK-7K öko 36 is a cast iron wood gasification boiler with a nominal heat output of 36 kW for water-based central heating systems. The combustion process operates on the wood gasification principle with bottom combustion and is designed for untreated log wood. The boiler body, made up of seven water-carrying cast iron sections, is manufactured in Germany. For the 36 kW version, a living space of 200 to 400 m² is given as a guideline; the specific boiler sizing must be based on the actual heat load and the system design.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eA lambda sensor monitors the combustion process, and the control system operates a modulating primary and secondary fan. The 4.3-inch touch control panel clearly displays the boiler temperature, buffer tank temperatures, and the operating status of the fans and the loading pump. The control system manages the buffer loading circuit pump and features a residual heat utilization program. The 140-liter loading chamber is designed for log wood up to 650 mm in length. Turbulators in the heat exchanger channels support heat transfer between the flue gas and the heating water.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe cast iron section design combines a robust boiler construction with the heat-storing properties of cast iron. The large loading chamber and wide loading door make it easier to load long pieces of log wood. The lambda control adjusts the primary and secondary air to the combustion process, while the central touch control consolidates the most important operating information. The door hinge is standard on the right and can be converted to the left as an ordering option.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe GK-7K öko 36 can be integrated as the main heat generator or together with a pellet, oil, or gas boiler, or a heat pump, into a correspondingly planned central heating system. For the 36 kW version, a buffer tank volume of at least 1,980 liters is specified. The hydraulics, return temperature raising, chimney, and safety devices must be matched to the boiler and the respective system design.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNominal heat output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e36 kW\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eNaturally seasoned log wood\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eCombustion technology\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eWood gasification with bottom combustion\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEfficiency at full load\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e91.52%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency index\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e119\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eAnnual space heating efficiency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e81 %\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eLog length\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eup to 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBoiler class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eRequired draft\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e10 Pa\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue gas temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e160–180 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue pipe connection\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e160 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBoiler connection flow\/return\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1 1\/2 inch\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eLambda sensor\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBuffer tank recommended\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMinimum buffer tank volume\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1,980 liters\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e230 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDimensions H × W × D\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1,224 × 832 × 1,345 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e800 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eInstallation, hydraulic integration, electrical connection and commissioning must be carried out by appropriately qualified specialist personnel. Before installation, the suitability of the chimney for the intended boiler must be checked. Buffer storage tanks and return temperature control must be designed to match the system. For closed heating systems, safety heat exchangers and thermal drain safety devices must be provided as required safety components.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eFor reliable wood gasification operation, suitable, sufficiently dry and untreated split logs must be used. The filling chamber, combustion chamber, heat exchanger areas, turbulators and flue gas passages must be regularly inspected and cleaned. The building size specification serves only as a guide and does not replace a heat load calculation or professional system planning.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eIBC GK-7K öko 36 boiler body, standing mounted on pallet\u003c\/li\u003e \u003cli\u003eBoiler casing\u003c\/li\u003e \u003cli\u003eBoiler control\u003c\/li\u003e \u003cli\u003eFan\u003c\/li\u003e \u003cli\u003eRefractory bricks for nozzle and combustion chamber area\u003c\/li\u003e \u003cli\u003eInstallation and operating instructions\u003c\/li\u003e \u003cli\u003eCleaning accessories\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"IBC","offers":[{"title":"Default Title","offer_id":47010471969116,"sku":"IBCGK745","price":9857.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/gema-shop-ibc-holzvergaserkessel-rot_1b37d53b-a1b2-48f7-b305-2ccea5a5628c.jpg?v=1787038360","url":"https:\/\/at.gemashop.de\/en\/products\/ibc-gk-7k-oeko-36-holzvergaser-36kw","provider":"GEMA Shop","version":"1.0","type":"link"}