{"product_id":"luft-wasser-waermepumpe-wolf-cha-monoblock-10-400-v","title":"Wolf CHA-Monoblock 10\/400 V air-to-water heat pump","description":"\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eProduct Overview \u0026amp; Application Range\u003c\/h2\u003e\n\u003cp\u003eThe Wolf CHA-Monoblock 10\/400 V is an air-to-water heat pump with matched indoor and outdoor units for space heating, domestic hot water preparation, and cooling operation. The heating output at A7\/W35 is 4.1 kW.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e\n\u003cp\u003eThe monoblock refrigeration circuit operates with the natural refrigerant R290. At A7\/W35, the COP is 5.72; the SCOP is 4.86 for W35 and 3.60 for W55. Flow temperatures up to 70 °C also enable use in many retrofit systems.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eEveryday Benefits\u003c\/h2\u003e\n\u003cp\u003eThe modulating heat pump combines high operating comfort with a wide range of applications. Heating and cooling operation as well as domestic hot water preparation are integrated into the system via the indoor hydraulics.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe CHA is designed for integration into water-based central heating systems and supports SG-Ready and PV-oriented operating modes. The BM-2 operating module is not included in the scope of delivery for the base unit configured here and will be added later as a separate accessory product.\u003c\/p\u003e\n\u003c\/div\u003e\u003cstyle\u003e.product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd}\u003c\/style\u003e\u003cdiv class=\"product-th\"\u003e\n\u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e\n\u003ctable class=\"product-th__table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeating output A7\/W35\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e4.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eCOP A7\/W35\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e5.72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSCOP W35\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e4.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSCOP W55\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3.60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. flow temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eR290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSound power level\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e53 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency class W35\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eA+++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency class W55\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eA++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cp\u003eIndoor and outdoor units, hydraulics, electrical supply, condensate drainage, and sound insulation must be planned and installed on a project-specific basis by qualified specialist personnel.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eNotes\u003c\/h2\u003e\n\u003cp\u003eThe WOLF CHA monoblock base unit is supplied without the BM-2 operating module. For complete system control, the appropriate control and system equipment must be planned separately in accordance with the system design. Until the accessory is created as a GEMA product, the \u0026quot;Accessory required\u0026quot; meta field remains set to FALSE in accordance with project rule 17.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eScope of delivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Wolf CHA monoblock outdoor unit 10\/400 V\u003c\/li\u003e\n\u003cli\u003e1 × corresponding Wolf CHA indoor unit\u003c\/li\u003e\n\u003cli\u003eThe BM-2 operating module and installation-dependent accessories are not included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Wolf","offers":[{"title":"Default Title","offer_id":58914631909724,"sku":"100AKW801","price":9437.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/gema-shop-wolf-cha-monoblock-waermepumpe_c6c12151-e6dc-4f3e-a187-5383771c4dc7.png?v=1788770034","url":"https:\/\/at.gemashop.de\/en\/products\/luft-wasser-waermepumpe-wolf-cha-monoblock-10-400-v","provider":"GEMA Shop","version":"1.0","type":"link"}