{"product_id":"tech-eu-81-zpid-hg-holzvergaserkessel-steuerung","title":"TECH EU-81 zPID HG boiler control for wood gasification boilers","description":"\u003cp data-start=\"1140\" data-end=\"1395\"\u003eThe \u003cstrong data-start=\"1144\" data-end=\"1166\"\u003eTECH EU-81 zPID HG\u003c\/strong\u003e is a microprocessor-controlled boiler control system with PID control, \u003cstrong data-start=\"1235\" data-end=\"1270\"\u003especifically for wood gasification boilers\u003c\/strong\u003e.  It controls the fan, heating and hot water pump and optimizes the combustion process via an additional exhaust gas sensor.\u003c\/p\u003e  \u003chr data-start=\"1397\" data-end=\"1400\"\u003e  \u003ch2 data-start=\"1402\" data-end=\"1428\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"1429\" data-end=\"1683\"\u003e⭐ Specifically designed for wood gasification boilers\u003cbr data-start=\"1472\" data-end=\"1475\"\u003e⭐ PID control with additional exhaust gas sensor\u003cbr data-start=\"1518\" data-end=\"1521\"\u003e⭐ Constant boiler temperature and stable operation\u003cbr data-start=\"1570\" data-end=\"1573\"\u003e⭐ Reduced emissions through optimized combustion\u003cbr data-start=\"1625\" data-end=\"1628\"\u003e⭐ Control of fan, heating and hot water pump\u003c\/p\u003e  \u003chr data-start=\"1685\" data-end=\"1688\"\u003e  \u003ch2 data-start=\"1690\" data-end=\"1718\"\u003eDetailed description\u003c\/h2\u003e  \u003ch3 data-start=\"1720\" data-end=\"1753\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h3\u003e  \u003cp data-start=\"1754\" data-end=\"2008\"\u003eThe EU-81 zPID HG is \u003cstrong data-start=\"1776\" data-end=\"1833\"\u003eexclusively for use with wood gasification boilers\u003c\/strong\u003e It is designed for use in residential heating systems as well as in technical applications where precise temperature and combustion control is required.\u003c\/p\u003e  \u003ch3 data-start=\"2010\" data-end=\"2034\"\u003eEveryday benefits\u003c\/h3\u003e  \u003cp data-start=\"2035\" data-end=\"2298\"\u003eThanks to the PID control with exhaust gas sensor, combustion is continuously monitored and adjusted. Temperature fluctuations are minimized, and the boiler operates more quietly and efficiently. This increases user comfort and ensures consistent heating operation.\u003c\/p\u003e  \u003ch3 data-start=\"2300\" data-end=\"2327\"\u003eTechnology \u0026amp; equipment\u003c\/h3\u003e  \u003cp data-start=\"2328\" data-end=\"2349\"\u003eThe control system regulates:\u003c\/p\u003e  \u003cul data-start=\"2350\" data-end=\"2431\"\u003e  \u003cli data-start=\"2350\" data-end=\"2372\"\u003e  \u003cp data-start=\"2352\" data-end=\"2372\"\u003ethe supply air (fan),\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2373\" data-end=\"2399\"\u003e  \u003cp data-start=\"2375\" data-end=\"2399\"\u003ethe heating circulation pump,\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2400\" data-end=\"2431\"\u003e  \u003cp data-start=\"2402\" data-end=\"2431\"\u003ethe hot water pump (boiler).\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2433\" data-end=\"2616\"\u003eAdditionally, an exhaust gas sensor continuously monitors the exhaust gas temperature. If the temperature rises, the fan speed is automatically reduced or switched off to prevent overheating.\u003c\/p\u003e  \u003ch3 data-start=\"2618\" data-end=\"2642\"\u003eEfficiency \u0026amp; Environment\u003c\/h3\u003e  \u003cp data-start=\"2643\" data-end=\"2884\"\u003eControlled combustion ensures consistent heat generation and can reduce fuel consumption. At the same time, emissions of dust particles and gases are reduced because the heat energy of the exhaust gases is utilized more efficiently.\u003c\/p\u003e  \u003ch3 data-start=\"2886\" data-end=\"2926\"\u003ecompatibility \u0026amp; System integration\u003c\/h3\u003e  \u003cp data-start=\"2927\" data-end=\"3170\"\u003eThe EU-81 zPID HG is designed for classic hydraulic heating systems with wood gasification boilers. Various operating modes, such as heating mode, parallel pumping, summer mode, or hot water priority, allow for flexible adaptation to the system.\u003c\/p\u003e  \u003chr data-start=\"3172\" data-end=\"3175\"\u003e  \u003ch2 data-start=\"3177\" data-end=\"3196\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3198\" data-end=\"3611\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3198\" data-end=\"3216\"\u003e  \u003ctr data-start=\"3198\" data-end=\"3216\"\u003e  \u003cth data-start=\"3198\" data-end=\"3208\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3208\" data-end=\"3216\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3234\" data-end=\"3611\"\u003e  \u003ctr data-start=\"3234\" data-end=\"3267\"\u003e  \u003ctd data-start=\"3234\" data-end=\"3247\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"3247\" data-end=\"3267\" data-col-size=\"sm\"\u003eTECH Controllers\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3268\" data-end=\"3294\"\u003e  \u003ctd data-start=\"3268\" data-end=\"3277\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"3277\" data-end=\"3294\" data-col-size=\"sm\"\u003eEU-81 zPID HG\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3295\" data-end=\"3327\"\u003e  \u003ctd data-start=\"3295\" data-end=\"3308\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"3308\" data-end=\"3327\" data-col-size=\"sm\"\u003eBoiler control\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3328\" data-end=\"3369\"\u003e  \u003ctd data-start=\"3328\" data-end=\"3346\" data-col-size=\"sm\"\u003epower supply\u003c\/td\u003e  \u003ctd data-start=\"3346\" data-end=\"3369\" data-col-size=\"sm\"\u003e230 V ±10 %\/50 Hz\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3370\" data-end=\"3397\"\u003e  \u003ctd data-start=\"3370\" data-end=\"3390\" data-col-size=\"sm\"\u003ePower consumption\u003c\/td\u003e  \u003ctd data-start=\"3390\" data-end=\"3397\" data-col-size=\"sm\"\u003e5 W\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3398\" data-end=\"3431\"\u003e  \u003ctd data-start=\"3398\" data-end=\"3420\" data-col-size=\"sm\"\u003eAmbient temperature\u003c\/td\u003e  \u003ctd data-start=\"3420\" data-end=\"3431\" data-col-size=\"sm\"\u003e5–50 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3432\" data-end=\"3458\"\u003e  \u003ctd data-start=\"3432\" data-end=\"3450\" data-col-size=\"sm\"\u003eMeasurement accuracy\u003c\/td\u003e  \u003ctd data-start=\"3450\" data-end=\"3458\" data-col-size=\"sm\"\u003e1 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3459\" data-end=\"3499\"\u003e  \u003ctd data-start=\"3459\" data-end=\"3490\" data-col-size=\"sm\"\u003eMax. load fan output\u003c\/td\u003e  \u003ctd data-start=\"3490\" data-end=\"3499\" data-col-size=\"sm\"\u003e0.6 A\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3500\" data-end=\"3540\"\u003e  \u003ctd data-start=\"3500\" data-end=\"3531\" data-col-size=\"sm\"\u003eMax.Pump output load\u003c\/td\u003e  \u003ctd data-start=\"3531\" data-end=\"3540\" data-col-size=\"sm\"\u003e0.5 A\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3541\" data-end=\"3588\"\u003e  \u003ctd data-start=\"3541\" data-end=\"3570\" data-col-size=\"sm\"\u003eTemperature range sensors\u003c\/td\u003e  \u003ctd data-start=\"3570\" data-end=\"3588\" data-col-size=\"sm\"\u003e-30 to +99 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3589\" data-end=\"3611\"\u003e  \u003ctd data-start=\"3589\" data-end=\"3601\" data-col-size=\"sm\"\u003eSecurity\u003c\/td\u003e  \u003ctd data-start=\"3601\" data-end=\"3611\" data-col-size=\"sm\"\u003e3.15 A\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"3613\" data-end=\"3616\"\u003e  \u003ch2 data-start=\"3618\" data-end=\"3635\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"3636\" data-end=\"3770\"\u003e  \u003cli data-start=\"3636\" data-end=\"3669\"\u003e  \u003cp data-start=\"3638\" data-end=\"3669\"\u003eBoiler control EU-81 zPID HG\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3670\" data-end=\"3699\"\u003e  \u003cp data-start=\"3672\" data-end=\"3699\"\u003eTemperature sensor (boiler)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3700\" data-end=\"3725\"\u003e  \u003cp data-start=\"3702\" data-end=\"3725\"\u003eExhaust gas temperature sensor\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3726\" data-end=\"3749\"\u003e  \u003cp data-start=\"3728\" data-end=\"3749\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3750\" data-end=\"3770\"\u003e  \u003cp data-start=\"3752\" data-end=\"3770\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3772\" data-end=\"3775\"\u003e  \u003ch2 data-start=\"3777\" data-end=\"3802\"\u003eAccessories\/Recommendation\u003c\/h2\u003e  \u003cul data-start=\"3803\" data-end=\"3967\"\u003e  \u003cli data-start=\"3803\" data-end=\"3830\"\u003e  \u003cp data-start=\"3805\" data-end=\"3830\"\u003eReplacement temperature sensor\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3831\" data-end=\"3856\"\u003e  \u003cp data-start=\"3833\" data-end=\"3856\"\u003eExhaust gas temperature sensor\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3857\" data-end=\"3895\"\u003e  \u003cp data-start=\"3859\" data-end=\"3895\"\u003eConnection cable and mounting material\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3896\" data-end=\"3967\"\u003e  \u003cp data-start=\"3898\" data-end=\"3967\"\u003eAdvanced control and safety technology for wood gasification boilers\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3969\" data-end=\"4018\"\u003eYou can find suitable accessories at \u003cstrong data-start=\"4002\" data-end=\"4017\"\u003egemashop.de\u003c\/strong\u003e.\u003c\/p\u003e  \u003chr data-start=\"4020\" data-end=\"4023\"\u003e  \u003ch2 data-start=\"4025\" data-end=\"4060\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"4061\" data-end=\"4313\"\u003eThe installation and commissioning may \u003cstrong data-start=\"4102\" data-end=\"4143\"\u003eonly by qualified specialists\u003c\/strong\u003e take place.\u003cbr data-start=\"4153\" data-end=\"4156\"\u003eThe control is \u003cstrong data-start=\"4174\" data-end=\"4215\"\u003eexclusively for wood gasification boilers\u003c\/strong\u003e planned.\u003cbr data-start=\"4227\" data-end=\"4230\"\u003eElectrical work may only be carried out when the system is de-energized.\u003c\/p\u003e  \u003chr data-start=\"4315\" data-end=\"4318\"\u003e  \u003ch2 data-start=\"4320\" data-end=\"4326\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"4328\" data-end=\"4422\"\u003e\u003cstrong data-start=\"4328\" data-end=\"4381\"\u003eFor which boilers is the EU-81 zPID HG suitable?\u003c\/strong\u003e\u003cbr data-start=\"4381\" data-end=\"4384\"\u003eExclusively for wood gasification boilers.\u003c\/p\u003e  \u003cp data-start=\"4424\" data-end=\"4587\"\u003e\u003cstrong data-start=\"4424\" data-end=\"4497\"\u003eHow does the HG variant differ from the standard EU-81 zPID?\u003c\/strong\u003e\u003cbr data-start=\"4497\" data-end=\"4500\"\u003eFunctionally identical, but clearly and exclusively intended for wood gasification boilers.\u003c\/p\u003e  \u003cp data-start=\"4589\" data-end=\"4688\"\u003e\u003cstrong data-start=\"4589\" data-end=\"4628\"\u003eWhich components are regulated?\u003c\/strong\u003e\u003cbr data-start=\"4628\" data-end=\"4631\"\u003eAir intake (fan), heating circulation pump and hot water pump.\u003c\/p\u003e  \u003cp data-start=\"4690\" data-end=\"4821\"\u003e\u003cstrong data-start=\"4690\" data-end=\"4729\"\u003eWhat is the function of the exhaust gas sensor?\u003c\/strong\u003e\u003cbr data-start=\"4729\" data-end=\"4732\"\u003eIt monitors the exhaust gas temperature and optimizes combustion and fan control.\u003c\/p\u003e  \u003cp data-start=\"4823\" data-end=\"4947\"\u003e\u003cstrong data-start=\"4823\" data-end=\"4861\"\u003eAre there different operating modes?\u003c\/strong\u003e\u003cbr data-start=\"4861\" data-end=\"4864\"\u003eYes, including heating operation, parallel pumps, summer mode and hot water priority.\u003c\/p\u003e  \u003cp data-start=\"4949\" data-end=\"5043\"\u003e\u003cstrong data-start=\"4949\" data-end=\"4986\"\u003eWho is authorized to install the control unit?\u003c\/strong\u003e\u003cbr data-start=\"4986\" data-end=\"4989\"\u003eInstallation must only be carried out by a specialist company.\u003c\/p\u003e  \u003chr data-start=\"5045\" data-end=\"5048\"\u003e  \u003ch2 data-start=\"5050\" data-end=\"5060\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"5061\" data-end=\"5282\"\u003eThe \u003cstrong data-start=\"5065\" data-end=\"5087\"\u003eTECH EU-81 zPID HG\u003c\/strong\u003e is a precise and reliable boiler control system for wood gasification boilers. It combines PID control with flue gas monitoring and offers safe, efficient control of modern wood heating systems.\u003c\/p\u003e","brand":"Tech","offers":[{"title":"Default Title","offer_id":47098276315484,"sku":"DE200HG","price":233.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/tech-eu-81-zpid-kesselsteuerung-pid-heizungsregler-mit-abgassensor-3873052.webp?v=1770693385","url":"https:\/\/at.gemashop.de\/en\/products\/tech-eu-81-zpid-hg-wood-gasifier-boiler-control","provider":"GEMA Shop","version":"1.0","type":"link"}